150mm IR Sensor Tap
- Sleek design at optimal length
- Easy installation and maintenance
- Robust design suits high-traffic public wash spaces
- Successful in commercial setting








Slim, aesthetic, market-leading, technologically advanced, and not an iPhone.
The sleek TSL.884 & TSL.886 Infrared Sensor Tap features an elegant, minimalist 150mm wall-mounted spout machined from AISI304 stainless steel. A separate sensor housing, also crafted in matching stainless steel, is designed to be affixed directly under the spout. This tap has been designed to work perfectly in a superloo environment alongside our Monolith Basin System, at an optimal length of 150mm
Easy to install, this WRAS approved infrared sensor tap can be operated using either mains or battery power and is robust enough to be suitable for high-traffic public or commercial washrooms. With a flow rate of 1.9L/min or 3.8L/min, an operating pressure of 0.2 to 8 Bar and an IR sensor range of 50mm to 120mm, it’s an easy-to-use washspace™ option. Both BREEAM and DDA compliant, this refined, minimalist tap comes in five metallic PVD finishes in brushed stainless steel.

Infrared sensor taps with contemporary finishes
The stylish WRAS approved TSL.884 IR sensor tap can be specified in five different finishes so you can achieve a public or commercial restroom with refined aesthetics. We offer coloured IR sensor taps in Black (BK), Brass, (BR), Copper (CP), Satin (CS).
We create our finishes using Physical Vapour Deposition (PVD). This process creates rich coloured stainless steel by coating it with Titanium Ion Plating. More environmentally friendly than electroplating or powder coating, this superior process improves the performance of stainless steel by increasing its durability and abrasion, scratch and corrosion resistance. The 0.5-micron thick coating hardens the surface, giving it good impact strength and making it so durable that protective topcoats are almost never necessary.
To specify your finish, please add the finish suffix to the main product code. For example, to order the TSL.884 IR Sensor Tap in Copper, the code would be TSL.884.CP.

How to create a consistent design look in your washroom
At The Splash Lab, we design and manufacture our own commercial washroom products that work together to create a consistent design language in your washspace™. We help you achieve consistency in your restroom not just through complementary product forms but also via our signature brushed stainless steel and curated palette of rich, coloured PVD finishes.
Our attention to detail, quality assurance and high level of craftsmanship results in simple design solutions that make public and commercial washroom environments better and more beautiful.

Can’t find the information you need?
Related projects
View allThe Splash Lab go above and beyond to make sure the end product is exactly as designed and functioning as intended.International Design Firm
Begin making the essential, exceptional
The sleek TSL.884 Infrared Sensor Tap features an elegant, minimalist 150mm wall-mounted spout machined from AISI304 stainless steel.
Download data sheet
Technical Data: Mechanical
Body Material
AISI 304 Stainless SteelCoating Type
PVDAerator
CascadeWater Pressure (Dynamic)
0.5 to 7.5 Bar [0.05 to 0.75MPa]Water Temperature (max)
60°CFlow Rates
0.5gpm [1.9L/min]Also available
0.35gpm [1.3L/min] – refer to Spare Parts & Accessories1.00gpm [3.8L/min] – refer to Spare Parts & Accessories
Weight
1041gTechnical Data: Electrical
Power supply
TSL .884 110-230 Vac, 50-60Hz, 1.5A TSL .886 6 V CR-P2 Lithium batteryOutput (max)
6 Vdc, 1APower consumption
< 87% Active mode, 0.3W No loadSolenoid valve type
6V LatchingWater Ingress
IP55Cable lengths
800mm – Power supply connection800mm – Solenoid valve connection
Technical drawings

Installation Guidlines
Wall Cut-out Hole Size
Ø16mm (Spigot)Ø40mm (Sensor Housing)
Depth of Wall Cavity (min)
100mmWall Thickness (max)
50mm (incl. finishes)Plumbing Connection
1⁄2” BSP (female) brass fitting is required to connect to the solenoid valve housingPower supply cable
To be hard wired in to fused connection unit (FCU) or spurWater supply
1.0 Bar is the recommended minimum pressure for the taps to operate effectively.7.5 Bar is the maximum pressure for commissioning and is NOT recommended for general use.
Gravity-fed systems may require a booster pump to achieve the optimal operating pressure
All pipework must be thoroughly cleaned and clear of any debris before connecting the tap.
Washroom layout
Solenoid valve must be accessible for installation, commissioning and ongoing maintenance.Avoid installing the sensor tap directly opposite other sensor taps, soap dispensers, infrared devices or reflective surfaces.
Careful consideration should be made when choosing the positioning of lighting and other reflective surfaces which may affect sensor performance.

Can’t find the information you need?
Related projects
View allThe Splash Lab go above and beyond to make sure the end product is exactly as designed and functioning as intended.International Design Firm